Mechanical Endurance Testing Setup
Endurance test benches are normally used for subsequent assessments of test specimens (measurable defects) after an appropriate operating life. These test benches can, also be equipped with suitable measuring devices for the continuous collection of the relevant data.
Salient Features:
GENERAL SPECIFICATIONS |
|
Purpose |
The apparatus is suitable to perform the following test: |
Power Input |
415 Volt AC, ±10%, 50Hz. i.e Three Phase |
Load Capacity |
4.6 kW, Single Phase, 50 Hz, 20 A |
Load Bank |
Resistive load having unity power factor,Inductive load having power factor 0.5 to 0.8 |
Metering |
Digital voltmeter: 0 - 300V, accuracy: ≤ ±0.5% Digital ammeter: 0 - 20A, accuracy: ≤ ±0.5% Digital power factor meter: up to 0.999, accuracy: ≤±0.5% |
Indications |
Audible/visible ‘End of Test’ indication |
Timer |
User programmable digital cyclic timer, 0-999 h/m/s ON &0-999 h/m/s OFF |
Wt. of instru. |
250kg approximately |
Construction |
M. S. Fabricated & Powder Coated moving Trolley |
Control |
Load Control: Switches or any other suitable means for selecting each load step |
Protection |
Overload / short circuit protection, Over temperature protection, Over voltage protection |
Warranty |
1 Year against manufacturing defects & Extended optional. |
Usage/Application | heck the condition of the insulation of switchgear and circuit breakers |
Display Type | Digital |
Frequency | 50/60 Hz |
Supply | AC |
Usage | Industrial,Laboratory |
Voltage | 230 V |
Display Type | Digital |
Supply | AC |
Overhaul Dimension | 2700 x 1900 x 2500 mm |
Inner Dimension | 1900 x 1100 x 2200 mm |
Usage | Industrial,Laboratory |
Usage/Application | Industrial, Endurance Test of Circuit Breaker |
Brand | Pragati Process Controls |
Model | BET |
Breaker ENDURANCE TESTING
Endurance testing is a testing technique, where a system is tested with a load extended over a significant amount of time, to analyze the behavior of the system under sustained use. This type of testing is performed at the last stage of performance run cycle. It ensures that the application is capable enough to handle the extended load without any deterioration of response time.
Silent Features:
GENERAL SPECIFICATIONS |
|
Power Input |
Voltage: 415 Volt AC, ±10%, 50Hz. i.e. Three Phase |
Voltage Adj.
|
Voltage adjustment by Common Auto Transformer for every Output |
Regulation
|
Better than-8% |
Output Ripple
|
Less than 1 RMS |
Metering |
Analog AC Voltmeter to show input Voltage |
PLC |
Function Controlled Timer |
Counter: |
Presentable Digital Counter for count a no. of operation. |
Indications |
Mains ‘ON’ indication, Audible/visible ‘End of Test’ indication |
Timer |
User programmable digital cyclic timer, 0-999 h/m/s ON & 0-999 h/m/s OFF |
Weight of Instrument |
250 kg, approximately. |
Size of Instrument |
550(W)*500(D)*1200(H) mm approximately. |
Construction |
M. S. Fabricated & Powder Coated moving Trolley |
Control |
Load Control: Switches or any other suitable means for selecting each load step |
Protection |
1.Flashing light for test ON 2.proper Fuse Links for output |
Warranty |
1 Year against manufacturing defects & Extended optional. |