Call 0804605985087% Response Rate
Send E-mail

Primary Current Injection Kit

A primary injection test is helpful for substations or circuits with high voltage and current. It is just the flow of rated current in the circuit under test.
Owing to our expertise in this field, our firm is engaged in supplying an extensive array of Primary Injection Kit

Get CALLBACK

Current Injection Source - 500 to 800 Amps

Current Injection Source - 500 to 800 Amps
 
Get Best Quote
Approx. Rs 1.2 Lakh / Number
Get Latest Price

Product Details:
Minimum Order Quantity1 Number
ModelPCI-500 to 800A
Usage/ApplicationCurrent Injection Source are specially designed for testing and calibration of CTS, relays, etc.
ColorAs per company standard
Display TypeDigital
BrandPRAGATI PROCESS CONTROLS
UsageIndustrial, Laboratory
SupplyAC
Frequency (MHz)50Hz
PhaseSingle Phase
Accuracy (%)Grater than 1.0Percent (F. S).
ControlWith the help of Manual Auto Transformer (according to customer demand)
Current Source10 to 800 Amp (according to customer demand).
MeasuringIsolated CT for current output, digital Voltmeter for voltage output
Output Power6.0V (according to customer demand). Up to 15kva
I Deal InNew Only
Protectiona)Overload b)Open circuit c)Over temp.
Timer Control Circuit Modes0.001 to 99999ms, Accuracy 0.1 Percent of reading Plus minus1ms
Warranty1 Year against manufacturing defects & Extended optional.
ConditionNew
Timer Stop InputVoltage input (24 to 300 V, DC or peak AC), drycontact input, or removal of primary current
Input voltageSingle phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand
External Current Meter range100A to 800 A, Accuracy 1 Percent of reading, Plus minus 20 mA
Operation time1min ON, 5mins OFF.
Country of OriginMade in India

PRIMARY CURRENT INJECTION Trolley-500 to 800A

PCI-300 to 500 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.

Salient Features:

  • ·All outputs continuously variable.
  • Time base multi range DIGITAL TIMER
  • True RMS digital metering of outputs
  • Compact rugged design
  • Auto-switch off in all modes of operation.
  • All current outputs fully isolated and distortion free.
  • Suitable for testing thermal devices
  • All controls and metering centralized.
Yes! I am interested
Get CALLBACK

Portable Primary Current Injector

Portable Primary Current Injector
 
Get Best Quote
Approx. Rs 85,000 / Number
Get Latest Price

Product Details:
Minimum Order Quantity1 Number
Packaging TypeWooden Box
UsageIndustrial
GradeManual
I Deal InNew Only
WeightAbout 37 kgs
Country of OriginMade in India

Product Details:

Usage Industrial
Power Source Electrical
Condition New
Display Type Digital
Frequency (MHz) 50 Hz
Phase Single Phase
Supply AC

PRIMARY CURRENT INJECTION SOURCE

Portable Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.

Salient Features:

  • · All outputs continuously variable.
  • · Time base multi range DIGITAL TIMER
  • · True RMS digital metering of outputs
  • · Compact rugged design
  • · Auto-switch off in all modes of operation.
  • · All current outputs fully isolated and distortion free.
  • · Suitable for testing thermal devices
  • · All controls and metering centralized.

 

GENERAL SPECIFICATIONS

Input voltage:

Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand

Current Source

10Milli Amp – 700 Amp (according to customer demand).

Output Power

Up to 3KV

Operation time:

1min ON, 5mins OFF.

Current accuracy

≤ 1.0% (F. S).

 

 

Timer Control Circuit Modes

0.001-99999ms, Accuracy: 0.1% of reading ±1ms

Normally Closed: Used to test a device with normally closed contacts.

Timer Stop Input

Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current

Protection

a) Overload

b) Open circuit

c) Over temp.

Measuring

Isolated CT for current output, digital Voltmeter for voltage output

External Current Meter range

100 mA – 700 A, Accuracy: 1% of reading, ±20 mA

Control

With the help of Manual Auto Transformer (according to customer demand)

Weight.

About 37kg

Warranty

1 Year against manufacturing defects & Extended optional.

 

 

Yes! I am interested
Get CALLBACK

Primary Injection Test Set-2000A-Portable

Primary Injection Test Set-2000A-Portable
 
Get Best Quote
Approx. Rs 1.6 Lakh / Number
Get Latest Price

Product Details:
Minimum Order Quantity1 Number
UsageIndustrial, Laboratory
Display TypeDigital
PhaseSingle Phase
SupplyAC
Frequency50Hz
Input230v
ModelPCI-2000 Portable Type
BrandPragati process Controls
ColorOrange
ControlWith the help of Manual Auto Transformer (according to customer demand)
Current Source10 to 2000 Amp (according to customer demand).
ConditionNew
MeasuringIsolated CT for current output, digital Voltmeter for voltage output
Output Power6.0V (according to customer demand). Up to 15kva
Protectiona) Overload b) Open circuit c) Over temp.
Timer Control Circuit Modes0.001 to 99999ms, Accuracy 0.1 Percent of reading Plus minus 1ms
Warranty1 Year against manufacturing defects & Extended optional.
Current accuracyGrater than 1.0 Percent (F. S).
Timer Stop InputVoltage input (24 to 300 V, DC or peak AC), drycontact input, or removal of primary current
Operation time1min ON, 5mins OFF.
Input voltageSingle phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand
External Current Meter range100A to 2000 A, Accuracy 1Percent of reading, Plus minus20 mA

PRIMARY INJECTION Test Set-2000A-Portable

PCI-2000 Portable Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.

Salient Features:

· All outputs continuously variable.

· Time base multi range DIGITAL TIMER

· True RMS digital metering of outputs

· Compact rugged design

· Auto-switch off in all modes of operation.

· All current outputs fully isolated and distortion free.

· Suitable for testing thermal devices

· All controls and metering centralized.

Yes! I am interested
Get CALLBACK

Primary Current Injection Source-5000A-Portable

Primary Current Injection Source-5000A-Portable
  • +1
 
Get Best Quote
Approx. Rs 2.8 Lakh / Number
Get Latest Price

Product Details:
Minimum Order Quantity1 Number
Display TypeDigital
BrandPRAGATI
UsageIndustrial, Laboratory
Input230v
Frequency50Hz
SupplyAC
PhaseSingle Phase
Accuracy (%)Grater than & equal to 1.0 Percent (F. S).
Input Voltage (V)Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand
ControlWith the help of Manual Auto Transformer (according to customer demand)
MeasuringIsolated CT for current output, digital Voltmeter for voltage output
Output Power6.0V (according to customer demand). Up to 15kva
Protectiona) Overload b) Open circuit c) Over temp.
Timer Control Circuit Modes0.001 to 99999ms, Accuracy 0.1Percent of reading plus minus 1ms
Warranty1 Year against manufacturing defects & Extended optional.
Timer Stop InputVoltage input (24 to 300 V, DC or peak AC), drycontact input, or removal of primary current
External Current Meter range100A to 500 A Accuracy 1 Percent of reading Plus minus20 mA
Operation time1min ON, 5mins OFF.

PRIMARY INJECTION Test Set-5000A-Portable

PCI-5000 Portable Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.

Salient Features:

· All outputs continuously variable.

· Time base multi range DIGITAL TIMER

· True RMS digital metering of outputs

· Compact rugged design

· Auto-switch off in all modes of operation.

· All current outputs fully isolated and distortion free.

· Suitable for testing thermal devices

· All controls and metering centralized.

 

Yes! I am interested
Get CALLBACK

Primary Current Injection Kit-1250Amps

Primary Current Injection Kit-1250Amps
  • +4
 
Get Best Quote
Approx. Rs 1.1 Lakh / Number
Get Latest Price

Product Details:
Minimum Order Quantity1 Number
Display TypeDigital
Phase3 Phase
Frequency (MHz)50 Hz
SupplyAC
ConditionNew
Power SourceElectrical

PRIMARY CURRENT INJECTION SOURCE

PCI-1250 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.

Salient Features:

  • · All outputs continuously variable.
  • · Time base multi range DIGITAL TIMER
  • · True RMS digital metering of outputs
  • · Compact rugged design
  • · Auto-switch off in all modes of operation.
  • · All current outputs fully isolated and distortion free.
  • · Suitable for testing thermal devices
  • · All controls and metering centralized.

 

GENERAL SPECIFICATIONS

Input voltage:

Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand

Current Source

10 – 1250 Amp (according to customer demand).

Output Power

6.0V (according to customer demand). Up to 15kva

Operation time:

1min ON, 5mins OFF.

Current accuracy

≤ 1.0% (F. S).

 

 

Timer Control Circuit Modes

0.001-99999ms, Accuracy: 0.1% of reading ±1ms

Normally Closed: Used to test a device with normally closed contacts. The timer stops and the output is de-energized when the contacts open.

Timer Stop Input

Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current

Protection

a) Overload

b) Open circuit

c) Over temp.

Measuring

Isolated CT for current output, digital Voltmeter for voltage output

External Current Meter range

100 mA – 1250 A, Accuracy: 1% of reading, ±20 mA

Control

With the help of Manual Auto Transformer (according to customer demand)

Weight.

About 100kg

Warranty

1 Year against manufacturing defects & Extended optional.

 

 

 

Yes! I am interested
Get CALLBACK

Primary Current Injection Set 1200A

Primary Current Injection Set 1200A
  • +2
 
Get Best Quote
Approx. Rs 1.45 Lakh / Piece
Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
WeightApproximately 60 Kg
BrandPragati
Accuracy+-1.0% of reading +-2 Digit
Output Power0 to 1200 Amp
ProtectionOpen Circuit Protection, Overload protection, Overheat Transformer protection
Warranty12 Months Against Manufacturing Defects & Extended optional
Indicator LampsInput ON, Current Injection ON, Overload Trip, Timer Trip
Country of OriginMade in India

Pragati's Primary Current Injection Set is a specialized testing device engineered for the precise and controlled injection of high electric currents into electrical systems and equipment. It is an essential tool for commissioning, maintenance, and troubleshooting of electrical power systems, ensuring the proper functioning of protective devices and overall system reliability.

Applications:Primary Current Injection Sets are used in various electrical testing and maintenance applications, including but not limited to:
  • Circuit Breaker Testing: Verifying the performance and tripping characteristics of circuit breakers.
  • Relay Testing: Ensuring the reliability of protection relays.
  • Ground Fault Protection Testing: Evaluating the response of ground fault protection systems.
  • Transformer Testing: Testing the performance of current transformers and potential transformers.
  • Switchgear Testing: Assessing the operation of switchgear components.
Yes! I am interested
Get CALLBACK

AC DC Voltage with Primary Current Injection Source

AC DC Voltage with Primary Current Injection Source
  • +3
 
Get Best Quote
Approx. Rs 2.3 Lakh / Number
Get Latest Price
Product Brochure

Product Details:
Minimum Order Quantity1 Number
Frequency (MHz)50 HZ
Voltage (V)220 V
SupplyAC
Driven TypeElectric

We are the leading and prominent Manufacturer and Supplier of ACDC Voltage with Primary Current Injection Source.
Yes! I am interested
Get CALLBACK

Primary Current Injection Trolley-300 to 500Amps

Primary Current Injection Trolley-300 to 500Amps
 
Get Best Quote
Approx. Rs 1.2 Lakh / PIECE
Get Latest Price

Product Details:
Minimum Order Quantity1 PIECE
Current Source10 to 500 Amp (according to customer demand).
Output Power6.0V (according to customer demand). Up to 15kva
Input voltageSingle phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand
Operation time1min ON, 5mins OFF.

PRIMARY CURRENT INJECTION SOURCE

PCI-300 to 500 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.

 

Salient Features:

  • · All outputs continuously variable.
  • · Time base multi range DIGITAL TIMER
  • · True RMS digital metering of outputs
  • · Compact rugged design
  • · Auto-switch off in all modes of operation.
  • · All current outputs fully isolated and distortion free.
  • · Suitable for testing thermal devices
  • · All controls and metering centralized.

 

Yes! I am interested
Get CALLBACK

Secondary Current + Primary Current Injection Source

Secondary Current + Primary Current Injection Source
 
Get Best Quote
Approx. Rs 2.35 Lakh / Set
Get Latest Price

Product Details:
Minimum Order Quantity1 Set
Voltage0-300 AC,0-300DC,0-10A AC,0-1000A AC
Frequency50HZ
Weight250Kg
Model Name/NumberAC-DC-PRI-SEC
Power6KVA
Tolerance0.5
Range0-300VAC
BrandPRAGATI PROCESS CONTROLS
Country of OriginMade in India

We are manufacturers of wide range of Primary Current-10-1000A +Secondary Current-0-1A-0-5A Injection Set to our clients.

General Specification
Make Pragati
Supply Input Three Phase 415V AC 50Hz (16 A at Full load) ±10%
Primary Current Injection Setting / Opration-Variable with the help Knob
Working duration-2 minutes On, 5 Min OFF.
Metering-3 ½ Digital Ammeter  0-10A
Protection-Overload protection with indication of Ovrload trip
Current Rating 10-1000A
CT Test Current 0-1A & 0-5A Continiously Variable (Three O/P Simultanaiously)
Pt Test Voltage  0-220V AC Between R-N ,Continiously Variable 
  0-220V AC Between Y-N ,Continiously Variable 
  0-220V AC Between B-N ,Continiously Variable
Single phase O/P Fix output protected with two pole MCB
Three Phase fix Output Fix output through 16A 3P+N+E ind Socket protected with Four pole MCB
Fabrication Robust enclosure M S Powder Coated & mounted on  lockable swivelling PU 4 inch castors. 
   

Additional Information:
  • Delivery Time: 4 Weeks
Yes! I am interested
Get CALLBACK

Primary Current Injection Kit Set-2000Amps

Primary Current Injection Kit Set-2000Amps
 
Get Best Quote
Approx. Rs 1 Lakh / Piece
Get Latest Price

Product Details:
Display TypeDigital
GradeAutomatic
Input Voltage (V)230 V
Frequency (MHz)50/60 Hz
SupplyAC
ConditionNew

PRIMARY CURRENT INJECTION SOURCE

PCI-2000 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.

Silent Features:

  • · All outputs continuously variable.
  • · Time base multi range DIGITAL TIMER
  • · True RMS digital metering of outputs
  • · Compact rugged design
  • · Auto-switch off in all modes of operation.
  • · All current outputs fully isolated and distortion free.
  • · Suitable for testing thermal devices
  • · All controls and metering centralized.

GENERAL SPECIFICATIONS

Input voltage:

Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand

Current Source

10 – 2000 Amp (according to customer demand).

Output Power

6.0V (according to customer demand). Up to 15kva

Operation time:

1min ON, 5mins OFF.

Current accuracy

≤ 1.0% (F. S).

External Current Meter range

100 mA – 2000 A, Accuracy: 1% of reading, ±20 mA

Timer Control Circuit Modes

0.001-99999ms, Accuracy: 0.1% of reading ±1ms

Normally Closed: Used to test a device with normally closed contacts. The timer stops and the output is de-energized when the contacts open.

Timer Stop Input

Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current

Protection

a) Overload

b) Open circuit

c) Over temp.

Measuring

Isolated CT for current output, digital Voltmeter for voltage output

External Current Meter range

100 mA – 2000 A, Accuracy: 1% of reading, ±20 mA

Control

With the help of Manual Auto Transformer (according to customer demand)

Weight.

About 400kg

Warranty

1 Year against manufacturing defects & Extended optional.

 

Yes! I am interested
Get CALLBACK

Primary Current with Temperature Rise Test

Primary Current with Temperature Rise Test
 
Get Best Quote
Approx. Rs 4.5 Lakh / Piece
Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
Display TypeDigital
BrandPRAGATI PROCESS CONTROLS
UsageIndustrial, Laboratory
ProtectionOverload and short circuit protection
Warranty1 Year against manufacturing defects & Extended optional.
ConditionNew

Primary Current with Temperature rise Test

PCI-2000 upto 5000 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.

Salient Features:

· All outputs continuously variable.

· Time base multi range DIGITAL TIMER

· True RMS digital metering of outputs

· Compact rugged design

· Auto-switch off in all modes of operation.

· All current outputs fully isolated and distortion free.

· Suitable for testing thermal devices

· All controls and metering centralized.

GENERAL SPECIFICATIONS

Input voltage:

Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand

Current Source

1 – 5000 Amp (according to customer demand).

Output Power

6.0V (according to customer demand). Up to 15kva

Operation time:

1min ON, 5mins OFF.

Current accuracy

≤ 1.0% (F. S).

External Current Meter range

Up to 2000A For Continuous

Above 2000A up to 5000A For 1min

Timer Control Circuit Modes

0.001-99999ms, Accuracy: 0.1% of reading ±1ms

Normally Closed: Used to test a device with normally closed contacts. The timer stops and the output is de-energized when the contacts open.

Timer Stop Input

Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current

Protection

a) Overload

b) Open circuit

c) Over temp.

Measuring

Isolated CT for current output, digital Voltmeter for voltage output

Control

With the help of Manual Auto Transformer (according to customer demand)

Weight.

About 400kg

Warranty

1 Year against manufacturing defects & Extended optional.

 

Yes! I am interested
Get CALLBACK

High Current Injection Source-6000Amps

High Current Injection Source-6000Amps
 
Get Best Quote
Approx. Rs 5.6 Lakh / Number
Get Latest Price

Product Details:
Minimum Order Quantity1 Number
Capacity20 KVA
Frequency (MHz)50/60 Hz
SupplyAC
ConditionNew

PRIMARY CURRENT INJECTION SOURCE

PCI-6000 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.

 

Salient Features:

  • · All outputs continuously variable.
  • · Time base multi range DIGITAL TIMER
  • · True RMS digital metering of outputs
  • · Compact rugged design
  • · Auto-switch off in all modes of operation.
  • · All current outputs fully isolated and distortion free.
  • · Suitable for testing thermal devices
  • · All controls and metering centralized.

GENERAL SPECIFICATIONS

Input voltage:

Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand

Current Source

10 – 6000 Amp (according to customer demand).

Output Power

6.0V (according to customer demand). Up to 15kva

Operation time:

1min ON, 5mins OFF.

Current accuracy

≤ 1.0% (F. S).

External Current Meter range

100 mA – 6000 A, Accuracy: 1% of reading, ±20 mA

Timer Control Circuit Modes

0.001-99999ms, Accuracy: 0.1% of reading ±1ms

Normally Closed: Used to test a device with normally closed contacts. The timer stops and the output is de-energized when the contacts open.

Timer Stop Input

Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current

Protection

a) Overload

b) Open circuit

c) Over temp.

Measuring

Isolated CT for current output, digital Voltmeter for voltage output

External Current Meter range

100 mA – 6000 A, Accuracy: 1% of reading, ±20 mA

Control

With the help of Manual Auto Transformer (according to customer demand)

Weight.

About 400kg

Warranty

1 Year against manufacturing defects & Extended optional.

 

Yes! I am interested
Get CALLBACK

Current Injection Source-1000Amps

Current Injection Source-1000Amps
 
Get Best Quote
Approx. Rs 1.5 Lakh / Number
Get Latest Price

Product Details:
Minimum Order Quantity1 Number
Type of Lighting ApplicationOutdoor Lighting
BrandPragati Process Controls
ColorOrange
Warranty1 Year against manufacturing defects & Extended optional.
Power SourceElectrical
Timer Control Circuit Modes0.001 to 99999ms Accuracy 0.1 percent of reading Plus Minus1ms
Protectiona) Overload b) Open circuit c) Over temp.
External Current Meter range100A to 500 A Accuracy1 Percent of reading Plus minus20 mA
Input voltageSingle phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand
Output Power6.0V (according to customer demand). Up to 15kva
Operation time1min ON, 5mins OFF.
ControlWith the help of Manual Auto Transformer (according to customer demand)
Current Source10 to1000 Amp (according to customer demand).
Timer Stop InputVoltage input (24 to 300 V, DC or peak AC), drycontact input, or removal of primary current
Current accuracyGrater than1.0 Percent (F. S).
MeasuringIsolated CT for current output, digital Voltmeter for voltage output

PRIMARY CURRENT INJECTION SOURCE

PCI-1000 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.

 

Salient Features:

  • · All outputs continuously variable.
  • · Time base multi range DIGITAL TIMER
  • · True RMS digital metering of outputs
  • · Compact rugged design
  • · Auto-switch off in all modes of operation.
  • · All current outputs fully isolated and distortion free.
  • · Suitable for testing thermal devices
  • · All controls and metering centralized.
Yes! I am interested
Explore More Products
X
Find UsYogesh Patil (Proprietor) PRAGATI PROCESS CONTROLS
Plot No. C9, Shop No. 110B, Globe Estate, Near Vikas Bus Stop, Dombivali, MIDC, Phase 1, Dombivli East, Dombivli - 421203, Thane, Maharashtra, India
SEND SMS
SEND E-MAIL
Share Us: