Our Primary Current Injection Kit is essential for testing and verifying the performance of high-voltage substations and circuits. Designed to handle rated current flows, this kit ensures accurate testing and calibration of protective relays, circuit breakers, and other critical components. Leveraging our extensive expertise, we offer a comprehensive range of Primary Current Injection Kits that deliver reliable performance and precision for demanding applications.
₹ 1500000 / Piece Get Latest Price
| Material | Computerised Current injector for short circuit test |
| Model Name/Number | PPC-ST-CT |
| Brand | Pragati |
| Grade | Automatic |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
₹ 230000 / Piece Get Latest Price
| Usage/Application | Industrial |
| Packaging Type | Wooden Box |
| Display Type | Digital |
| Grade | Manual |
| Frequency (MHz) | 50 HZ |
| Voltage (V) | 220 V |
| Supply | AC |
| Driven Type | Electric |
Minimum order quantity: 1 Piece
An AC/DC voltage source with a primary current injection trolley is a specialized testing device used primarily in electrical engineering and maintenance. Here's a brief overview:
Key Features:
Applications:
Benefits:
₹ 160000 / Number Get Latest Price
| Display Type | Digital |
| Usage | Laboratory, Industrial |
| Phase | Single Phase |
| Supply | AC |
| Frequency | 50Hz |
| Input | 230v |
| Model | PCI-2000 Portable Type |
| Brand | Pragati process Controls |
| Color | Orange |
| Control | With the help of Manual Auto Transformer (according to customer demand) |
| Current Source | 10 to 2000 Amp (according to customer demand). |
| Condition | New |
| Measuring | Isolated CT for current output, digital Voltmeter for voltage output |
| Output Power | 6.0V (according to customer demand). Up to 15kva |
| Protection | a) Overload b) Open circuit c) Over temp. |
| Timer Control Circuit Modes | 0.001 to 99999ms, Accuracy 0.1 Percent of reading Plus minus 1ms |
| Warranty | 1 Year against manufacturing defects & Extended optional. |
| Input voltage | Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand |
| Timer Stop Input | Voltage input (24 to 300 V, DC or peak AC), drycontact input, or removal of primary current |
| Operation time | 1min ON, 5mins OFF. |
| Current accuracy | Grater than 1.0 Percent (F. S). |
| External Current Meter range | 100A to 2000 A, Accuracy 1Percent of reading, Plus minus20 mA |
Minimum order quantity: 1 Number
PRIMARY INJECTION Test Set-2000A-Portable
PCI-2000 Portable Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.
Salient Features:
· All outputs continuously variable.
· Time base multi range DIGITAL TIMER
· True RMS digital metering of outputs
· Compact rugged design
· Auto-switch off in all modes of operation.
· All current outputs fully isolated and distortion free.
· Suitable for testing thermal devices
· All controls and metering centralized.
₹ 400000 / Piece Get Latest Price
| Frequency | 50 Hz |
| Weight | 155 Kg Approx. |
| I Deal In | New Only |
| Protection | Open Circuit Protection, Overload Protection, Overheat Transformer Protection |
| Country of Origin | Made in India |
| Input voltage | Single Phase 230V AC @ 25A |
| Output Current | 0 to 1000 Amp (according to client requirement) |
| Fabrication | Powder coated MS fabricated moving trolley |
Minimum order quantity: 1 Piece
A primary current injection trolley is a specialized testing device used to assess the performance and reliability of protective relays, circuit breakers, and other electrical equipment. This equipment is particularly crucial in ensuring that protection systems operate correctly under fault conditions.
Key Features and Functions:
High Current Output: We design trolley's that can produce high current levels necessary for testing protective devices, simulating fault conditions.
Mobility: Being a trolley, it is designed for easy transport, making it convenient for field testing and maintenance.
User Interface: We design models that come equipped with user-friendly displays and controls, allowing technicians to set parameters and monitor testing in real-time.
Safety Features: We include various safety mechanisms to protect both the operator and the equipment during testing.
Versatility: Can be used for various testing applications, including relay testing, circuit breaker testing, and verifying current transformer ratios.
Data Logging: We also design models that have the capability to log data during testing for later analysis, which is useful for maintenance records and compliance documentation.
₹ 280000 / Number Get Latest Price
| Display Type | Digital |
| Brand | PRAGATI |
| Usage | Industrial, Laboratory |
| Input | 230v |
| Frequency | 50Hz |
| Supply | AC |
| Phase | Single Phase |
| Accuracy (%) | Grater than & equal to 1.0 Percent (F. S). |
| Input Voltage (V) | Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand |
| Control | With the help of Manual Auto Transformer (according to customer demand) |
| Measuring | Isolated CT for current output, digital Voltmeter for voltage output |
| Output Power | 6.0V (according to customer demand). Up to 15kva |
| Protection | a) Overload b) Open circuit c) Over temp. |
| Timer Control Circuit Modes | 0.001 to 99999ms, Accuracy 0.1Percent of reading plus minus 1ms |
| Warranty | 1 Year against manufacturing defects & Extended optional. |
| Operation time | 1min ON, 5mins OFF. |
| External Current Meter range | 100A to 500 A Accuracy 1 Percent of reading Plus minus20 mA |
| Timer Stop Input | Voltage input (24 to 300 V, DC or peak AC), drycontact input, or removal of primary current |
Minimum order quantity: 1 Number
PRIMARY INJECTION Test Set-5000A-Portable
PCI-5000 Portable Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.
Salient Features:
· All outputs continuously variable.
· Time base multi range DIGITAL TIMER
· True RMS digital metering of outputs
· Compact rugged design
· Auto-switch off in all modes of operation.
· All current outputs fully isolated and distortion free.
· Suitable for testing thermal devices
· All controls and metering centralized.
₹ 145000 / Piece Get Latest Price
| Weight | Approximately 60 Kg |
| Brand | Pragati |
| Accuracy | +-1.0% of reading +-2 Digit |
| Output Power | 0 to 1200 Amp |
| Protection | Open Circuit Protection, Overload protection, Overheat Transformer protection |
| Warranty | 12 Months Against Manufacturing Defects & Extended optional |
| Country of Origin | Made in India |
| Indicator Lamps | Input ON, Current Injection ON, Overload Trip, Timer Trip |
Minimum order quantity: 1 Piece
₹ 450000 / Piece Get Latest Price
| Display Type | Digital |
| Brand | PRAGATI PROCESS CONTROLS |
| Usage | Industrial, Laboratory |
| Protection | Overload and short circuit protection |
| Warranty | 1 Year against manufacturing defects & Extended optional. |
| Condition | New |
Minimum order quantity: 1 Piece
Pragati Process Controls have developed TEMPERATURE RISE TEST PANEL to carry out temperature rise test for low voltage switchgear items. It consists of True RMS constant Current source, which maintains the Current with + / - 1 % of set value with Digital indication, Digital Temperature indicator having twelve channels for temperature measurement. Cr/Al' types of thermocouple sensors are used for temperature sensing. Digital voltmeter used to indicate position of autotransformer.
₹ 110000 / Number Get Latest Price
| Display Type | Digital |
| Phase | 3 Phase |
| Frequency (MHz) | 50 Hz |
| Supply | AC |
| Condition | New |
| Power Source | Electrical |
Minimum order quantity: 1 Number
PRIMARY CURRENT INJECTION SOURCE
PCI-1250 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.
Salient Features:
|
GENERAL SPECIFICATIONS |
|
|
Input voltage: |
Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand |
|
Current Source |
10 – 1250 Amp (according to customer demand). |
|
Output Power |
6.0V (according to customer demand). Up to 15kva |
|
Operation time: |
1min ON, 5mins OFF. |
|
Current accuracy |
≤ 1.0% (F. S). |
|
|
|
|
Timer Control Circuit Modes |
0.001-99999ms, Accuracy: 0.1% of reading ±1ms |
|
Normally Closed: Used to test a device with normally closed contacts. The timer stops and the output is de-energized when the contacts open. |
|
|
Timer Stop Input |
Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current |
|
Protection |
a) Overload b) Open circuit c) Over temp. |
|
Measuring |
Isolated CT for current output, digital Voltmeter for voltage output |
|
External Current Meter range |
100 mA – 1250 A, Accuracy: 1% of reading, ±20 mA |
|
Control |
With the help of Manual Auto Transformer (according to customer demand) |
|
Weight. |
About 100kg |
|
Warranty |
1 Year against manufacturing defects & Extended optional. |
₹ 85000 / Number Get Latest Price
| Packaging Type | Wooden Box |
| Usage | Industrial |
| Grade | Manual |
| I Deal In | New Only |
| Weight | About 37 kgs |
| Country of Origin | Made in India |
Minimum order quantity: 1 Number
Product Details:
| Usage | Industrial |
| Power Source | Electrical |
| Condition | New |
| Display Type | Digital |
| Frequency (MHz) | 50 Hz |
| Phase | Single Phase |
| Supply | AC |
PRIMARY CURRENT INJECTION SOURCE
Portable Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.
Salient Features:
|
GENERAL SPECIFICATIONS |
|
|
Input voltage: |
Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand |
|
Current Source |
10Milli Amp – 700 Amp (according to customer demand). |
|
Output Power |
Up to 3KV |
|
Operation time: |
1min ON, 5mins OFF. |
|
Current accuracy |
≤ 1.0% (F. S). |
|
|
|
|
Timer Control Circuit Modes |
0.001-99999ms, Accuracy: 0.1% of reading ±1ms |
|
Normally Closed: Used to test a device with normally closed contacts. |
|
|
Timer Stop Input |
Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current |
|
Protection |
a) Overload b) Open circuit c) Over temp. |
|
Measuring |
Isolated CT for current output, digital Voltmeter for voltage output |
|
External Current Meter range |
100 mA – 700 A, Accuracy: 1% of reading, ±20 mA |
|
Control |
With the help of Manual Auto Transformer (according to customer demand) |
|
Weight. |
About 37kg |
|
Warranty |
1 Year against manufacturing defects & Extended optional. |
₹ 400000 / Piece Get Latest Price
| Packaging Type | Wooden Box |
| Color | Grey (Can be designed as per client demand) |
| Model | PPC-PCI |
| Frequency | 50Hz |
| Weight | 155 Kg Approx. |
| Input Supply | Three Phase 415V AC @ 25A |
| Brand | Pragati Process Control |
| Control | With the help of Manual Auto Transformer (according to customer demand) |
| Current Source | 10 to 800 Amp (according to customer demand). |
| I Deal In | New Only |
| Protection | Open Circuit Protection, Overload Protection, Overheat Transformer Protection |
| Warranty | 1 Year against manufacturing defects & Extended optional |
| Phase | Three Phase |
| Frequency (MHz) | 50Hz |
| Supply | AC |
| Condition | New |
| Country of Origin | Made in India |
| Output Current | 0 to 1000 Amp |
| Fabrication | Powder Coated MS Fabricated mounted on movable wheels |
Minimum order quantity: 1 Piece
A PLC (Programmable Logic Controller) based Primary Current Injection Test System combines the benefits of primary current injection testing with the programmability and automation capabilities of PLCs. This integration allows for more sophisticated control, monitoring, and data management during testing processes.
Key Features:
Programmable Control:
The PLC allows for customized test sequences, making it easy to configure tests according to specific requirements.
Users can program various test scenarios, including different current levels and durations.
Automation:
Automates repetitive testing processes, reducing human error and increasing efficiency.
Enables scheduled tests, ensuring regular maintenance and compliance.
Real-time Monitoring:
The PLC can continuously monitor current, voltage, and other parameters during tests.
Alarms and notifications can be set up for out-of-range conditions.
Data Logging and Analysis:
Captures test data for later analysis, enabling trend analysis and performance evaluations over time.
Data can be exported to various formats for reporting.
User Interface:
Typically features a user-friendly interface for easy operation, allowing engineers to configure tests quickly.
Include touchscreens or computer interfaces for real-time visualization of test parameters.
Applications:
Protection Relay Testing: Evaluating the performance of protection relays under various fault conditions.
Circuit Breaker Testing: Ensuring that circuit breakers function correctly and trip at specified current levels.
Transformer Testing: Assessing insulation integrity and operational characteristics of transformers.
₹ 210000 / Piece Get Latest Price
| Output Current | 0-3000 Amp |
| Warranty | 12 Months Against Manufacturing Defects |
| Weight | 80 - 90 Kg Approx. |
| Country of Origin | Made in India |
| Supply Input | Single Phase 230V AC @ 80A, 50Hz |
| Accuracy | +-1.0% |
| Protection | Open Circuit Protection, Overload Protection, Overheat Transformer Protection |
| Fabrication | Powder Coated MS Fabricated |
Minimum order quantity: 1 Piece
CURRENT INJECTION SOURCE Set-3000A
PCI-3000 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.
Salient Features:
· All outputs continuously variable.
· Time base multi range DIGITAL TIMER
· True RMS digital metering of outputs
· Compact rugged design
· Auto-switch off in all modes of operation.
· All current outputs fully isolated and distortion free.
· Suitable for testing thermal devices
· All controls and metering centralized.
|
GENERAL SPECIFICATIONS |
|
|
Input voltage: |
Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand |
|
Current Source |
10 – 3000 Amp (according to customer demand). |
|
Output Power |
6.0V (according to customer demand). Up to 15kva |
|
Operation time: |
1min ON, 5mins OFF. |
|
Current accuracy |
≤ 1.0% (F. S). |
|
External Current Meter range |
100 mA – 3000 A, Accuracy: 1% of reading, ±20 mA |
|
Timer Control Circuit Modes |
0.001-99999ms, Accuracy: 0.1% of reading ±1ms |
|
Normally Closed: Used to test a device with normally closed contacts. The timer stops and the output is de-energized when the contacts open. |
|
|
Timer Stop Input |
Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current |
|
Protection |
a) Overload b) Open circuit c) Over temp. |
|
Measuring |
Isolated CT for current output, digital Voltmeter for voltage output |
|
External Current Meter range |
100 mA – 3000 A, Accuracy: 1% of reading, ±20 mA |
|
Control |
With the help of Manual Auto Transformer (according to customer demand) |
|
Weight. |
About 400kg |
|
Warranty |
1 Year against manufacturing defects & Extended optional. |
₹ 100000 / Piece Get Latest Price
| Display Type | Digital |
| Grade | Automatic |
| Input Voltage (V) | 230 V |
| Frequency (MHz) | 50/60 Hz |
| Supply | AC |
| Condition | New |
PRIMARY CURRENT INJECTION SOURCE
PCI-2000 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.
Silent Features:
|
GENERAL SPECIFICATIONS |
|
|
Input voltage: |
Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand |
|
Current Source |
10 – 2000 Amp (according to customer demand). |
|
Output Power |
6.0V (according to customer demand). Up to 15kva |
|
Operation time: |
1min ON, 5mins OFF. |
|
Current accuracy |
≤ 1.0% (F. S). |
|
External Current Meter range |
100 mA – 2000 A, Accuracy: 1% of reading, ±20 mA |
|
Timer Control Circuit Modes |
0.001-99999ms, Accuracy: 0.1% of reading ±1ms |
|
Normally Closed: Used to test a device with normally closed contacts. The timer stops and the output is de-energized when the contacts open. |
|
|
Timer Stop Input |
Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current |
|
Protection |
a) Overload b) Open circuit c) Over temp. |
|
Measuring |
Isolated CT for current output, digital Voltmeter for voltage output |
|
External Current Meter range |
100 mA – 2000 A, Accuracy: 1% of reading, ±20 mA |
|
Control |
With the help of Manual Auto Transformer (according to customer demand) |
|
Weight. |
About 400kg |
|
Warranty |
1 Year against manufacturing defects & Extended optional. |
₹ 560000 / Piece Get Latest Price
| Capacity | 20 KVA |
| Frequency (MHz) | 50/60 Hz |
| Supply | AC |
| Condition | New |
Minimum order quantity: 1 Piece
PRIMARY CURRENT INJECTION SOURCE
PCI-6000 Manual Primary Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes. Our Primary Current Injection Test Sets are used for loading, calibration and testing of CT's bimetals relays etc.
Salient Features:
|
GENERAL SPECIFICATIONS |
|
|
Input voltage: |
Single phase 230V AC, 50Hz Protected with MCB & HRC fuse , or as per customer demand |
|
Current Source |
10 – 6000 Amp (according to customer demand). |
|
Output Power |
6.0V (according to customer demand). Up to 15kva |
|
Operation time: |
1min ON, 5mins OFF. |
|
Current accuracy |
≤ 1.0% (F. S). |
|
External Current Meter range |
100 mA – 6000 A, Accuracy: 1% of reading, ±20 mA |
|
Timer Control Circuit Modes |
0.001-99999ms, Accuracy: 0.1% of reading ±1ms |
|
Normally Closed: Used to test a device with normally closed contacts. The timer stops and the output is de-energized when the contacts open. |
|
|
Timer Stop Input |
Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current |
|
Protection |
a) Overload b) Open circuit c) Over temp. |
|
Measuring |
Isolated CT for current output, digital Voltmeter for voltage output |
|
External Current Meter range |
100 mA – 6000 A, Accuracy: 1% of reading, ±20 mA |
|
Control |
With the help of Manual Auto Transformer (according to customer demand) |
|
Weight. |
About 400kg |
|
Warranty |
1 Year against manufacturing defects & Extended optional. |
₹ 235000 / Piece Get Latest Price
| Voltage | 0-300 AC,0-300DC,0-10A AC,0-1000A AC |
| Frequency | 50HZ |
| Weight | 250Kg |
| Model Name/Number | AC-DC-PRI-SEC |
| Power | 6KVA |
| Tolerance | 0.5 |
| Range | 0-300VAC |
| Brand | PRAGATI PROCESS CONTROLS |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
| General Specification | |
| Make | Pragati |
| Supply Input | Three Phase 415V AC 50Hz (16 A at Full load) ±10% |
| Primary Current Injection | Setting / Opration-Variable with the help Knob |
| Working duration-2 minutes On, 5 Min OFF. | |
| Metering-3 ½ Digital Ammeter 0-10A | |
| Protection-Overload protection with indication of Ovrload trip | |
| Current Rating | 10-1000A |
| CT Test Current | 0-1A & 0-5A Continiously Variable (Three O/P Simultanaiously) |
| Pt Test Voltage | 0-220V AC Between R-N ,Continiously Variable |
| 0-220V AC Between Y-N ,Continiously Variable | |
| 0-220V AC Between B-N ,Continiously Variable | |
| Single phase O/P | Fix output protected with two pole MCB |
| Three Phase fix Output | Fix output through 16A 3P+N+E ind Socket protected with Four pole MCB |
| Fabrication | Robust enclosure M S Powder Coated & mounted on lockable swivelling PU 4 inch castors. |
Yogesh Patil (Proprietor)
PRAGATI PROCESS CONTROLS
Plot No. C9, Shop No. 110B, Globe Estate, Near Vikas Bus Stop, Dombivali, MIDC, Phase 1
Dombivli - 421203, Thane, Maharashtra, India