Secondary injection tests are performed to verify the correct operation of the protection system with regard to everything that is connected to the secondary of the transformers.
We are equipped in manufacturing high quality secondary injection test sets as per clients requirements.




₹ 500000 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Packaging Type | Wooden Box |
| Material | MS Fabricated |
| Usage/Application | Industrial |
| Brand | Pragati |
| Model Name/Number | PPC-SIT |
| I Deal In | New Only |
| Country of Origin | Made in India |
The secondary protection system may comprise protective relays, auxiliary relays, protection circuits, communication and control systems, metering devices, low-voltage components, alarms, and more. Consequently, the secondary injection test not only assesses the protective relays and their trip settings but also verifies the functionality of all related circuits and devices essential for the effective operation of the secondary protection system.
Key Features:







₹ 550000 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Weight | 90 To 100 Kg Approx. |
| Brand | Pragati |
| Country of Origin | Made in India |
| Supply Input | Three Phase 415V AC 50Hz ( 20A at Full load) +-10% |
| Protection | MCB & Glass Fuses are provided for short circuit protection, CT operated overload protection |
| Fabrication | Powder Coated MS fabricated moving trolleys |
| Dimension | 500(W)*500(D)*1000(H) MM Approx. |








₹ 135000 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Current Output | 10AMP, 25AMP, 50 AMP. |
| Model Name/Number | PPC-SCI |
| Shape | Industrial Carrying Case |
| Output Voltage | a) 0-415VAC Phase To Phase With respective Neutral 0-230VAC b) 0-230 VAC c) 0-300 VDC d) 110 |
| Brand | Pragati |
| Material | Aluminium |
| Country of Origin | Made in India |
| WEIGHT | 35 To 40 Kg Approximately |
| DIAMENSION | 550 X 450 X 200 MM Approximately |
| Type | Portable |



₹ 100000 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Brand | Pragati Process Controls |
| Weight | Depends on the design of the system |
| Material | MS Fabricated |
| Model | PPC-SCI |
| Color | According to client requirement |
| Country of Origin | Made in India |
Secondary Current Injection Test Set
A Secondary Current Injection Test Set is a specialized tool used to verify the functionality and performance of protective relays and associated protection systems in electrical installations. This testing equipment ensures that protective devices operate correctly under fault conditions.
We manufacture Secondary Current Injection Test Sets in various designs to meet diverse needs, including:
Applications:


₹ 350000 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Voltage | Output Voltage Range: 0 to 300 V |
| Frequency | 45 to 60 Hz |
| Weight | Approx. 40 Kg |
| Model Name/Number | PPC-SI |
| Material | Enclosure is Powder coated sheet steel SWG 16 with lifting handles |
| Current output | Output Current Range: 0 to 5.0 Amp AC per phase |
| Country of Origin | Made in India |
| Brand | Pragati Process Controls |
Secondary Injection Kit
It is a method of connecting a secondary injection test set to a trip unit (trip device, over current module, protection device, OCR, ETU etc.) on a circuit breaker and injecting a simulated current to prove it works at different levels.
Salient Features:
General Specification | |
Supply Input | Three Phase 380 to 440V AC 50Hz ±10%, Mains MCB to Power ON the Panel |
Output Voltage Range: | 0 to 300 V (L-N) or 0 to 520 Phase to Phase , 3 knobs to control individual voltage magnitude |
Output Current Range: | 0 to 5.0 Amp AC per phase |
Frequency: | 45 to 60 Hz |
Output ports: | Vr ,Vy, Vb - N, Ir (Hi, Lo),Iy (Hi, Lo),Ib (Hi, Lo) |
Compliance: | 40 VA, at FS on V ranges & on A channels |
Accuracy: | Class 0.25% (for V, A, W and Whr ) |
Sinusoidal Outputs: | THD 1.5% |
Protections: | Overload and Short circuit |
Setting: | Setting: By coarse and fine set of potentiometer for Voltage and Current |
Digital Timer: | With External Start / Stop Signal Input facility Resolution 1 m Sec Auto ranging model Select- TI103C (48*96) |
Phase Seq: | Phase Seq indicator with ext. input.- minilec- |
Amp meter: | 4-20 Mille amp meter for Transducer output measurement |
Fabrication | Enclosure is Powder coated sheet steel SWG 16 with lifting handles |
Dimension : | (500W X 200H X 450D)mm. |
Weight : | Weight of equipment Approx. 40 Kg. |
Wiring | LFH Black wire to be used |





₹ 100000 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Brand | Pragati Process Controls |
Secondary Current Injection Source
The secondary protection system may include Protective Relays, auxiliary relays, protection circuits, communications and control systems, metering devices, low-voltage devices, alarms, etc. Accordingly, the secondary injection test covers not only the testing of protective relays and their tripping settings, but also the checking of all associated circuits and devices involved in the proper performance of the secondary protection system.
Salient Features:
|
General Specification |
|
|
Input voltage |
Three Phase 415V AC 50Hz (2 A at Full load) ±10% |
|
CT Test Current |
0-1A & 0-5A & 0-10A Continuously Variable (Three O/p Simultaneously) Suitable to test max range of 20VA CT Output R, Y, B Phases and neutral is provided with ON/OFF facility (for various fault simulations as 3Ø & N, 2Ø & N, 1Ø & N, only 3Ø, only 2Ø etc. Digital timer for switching time measurement in milliseconds. Resolution 0.01 Sec. it will start count till aux contact is open 3 ½ Digital Ammeter 0-10A |
|
PT Test Voltage |
0-220V AC Between R-N,Y-N,B-Continuously Variable. With the help of Manual Auto Transformer. Each phase require separate single phase auto transformer |
|
DC Voltage For Numerical Relay Testing |
Output voltage 5-230V DC Output current 0-5A Output Ripple CV 5mV RMS maximum Metering 3½ digit AC Ammeter, 3½ digit AC Voltmeter Protection Output overload protection Output short circuit protection Output overvoltage trip |
|
Single phase Output |
Fix output protected with two pole MCB, Emergency Stop on front of Control Trolley |
|
Fabrication |
Robust enclosure M S Powder Coated & mounted on lockable swiveling PU 4 inch castors. |


Yogesh Patil (Proprietor)
PRAGATI PROCESS CONTROLS
Plot No. C9, Shop No. 110B, Globe Estate, Near Vikas Bus Stop, Dombivali, MIDC, Phase 1, Dombivli - 421203, Thane, Maharashtra, India